HCV-E-ST-AX

Oliepeilglazen elektrisch

Omschrijving

1Main specifications

Material

Transparent polyamide based (PA-T) technopolymer. Highly resistant to shocks, solvents, oils with additives, aliphatic and aromatic hydrocarbons, petrol, naphtha, phosphoric esters.

Avoid contact with alcohol or detergents containing alcohol.

Screws, nuts and washers

Zinc-plated steel.

Packing rings

Step-shaped for the seal on the reservoir walls and NBR synthetic rubber O-ring screw underhead.

Suggested roughness of the packing ring application surface Ra = 3 µm.

Float

Glass-fibre reinforced polyamide based (PA) technopolymer, black colour, with a built-in magnetic element to activate the electric contact when the float reaches the contact threshold located at about 50 mm above the axis of the lower screw (data referred to mineral oil type CB68, according to ISO 3498, temperature 23°C).

Bracket with level and temperature sensors.

Watertight in glass-fibre reinforced polyamide based (PA) technopolymer, black colour, with a built-in relay (reed) with two conductors and a MAX temperature sensor (80°C).

For a correct assembly see Warnings.

Swivelling connector

With built-in cable gland and contact holders. Front or side output (right or left) including protection against water sprays (protection class IP 65 according to EN 60529).

Contrast screen

White lacquered aluminium. The housing, in the appropriate external rear slot, guarantees the best protection from direct contact with fluid.

It can be taken out from the inclined side, before assembly to allow the insertion of level lines or words.

Standard executions

  • HCV-E-ST-AX-NO: with electric contacts normally open (NO).
  • HCV-E-ST-AX-NC: with electric contacts normally closed (NC).

Maximum continuous working temperature

90°C (with oil).

2General information

Features and performances

In addition to the visual control, HCV-E-ST-AX oil electrical level indicator, generates also an electric signal when the oil level drops to a minimum and an electric signal when the temperature reaches the max pre-set degrees (80°C).

Ultrasound welding to guarantee a perfect seal.

Maximum fluid level visibility even from side positions.

Lens effect for a better visibility of the fluid level.

Technical data

In laboratory tests carried out with mineral oil type CB68 (according to ISO 3498) at 23°C for a limited period of time, the weld stood up to 18 bar.

For use with other fluids and under different pressure and temperature conditions, please contact ELESA Technical Department.

In any case we suggest to verify the suitability of the product under the actual working conditions.

3Electrical features

Functioning of the sensors

  • HCV-E-ST-AX-NO: the electrical contact closes when the minimum level and/or the pre-set temperature at 80°C is reached.
  • HCV-E-ST-AX-NC: the electrical contact opens when the minimum level and/or the pre-set temperature at 80°C is reached.
Electrical featuresMIN level sensor
Power supplyAC/DC
Electric contacts

NO normally open

NC normally closed

Maximum applicable voltage

NO: 140 Vac, 200 Vdc

NC: 140Vac, 150 Vdc

Maximum switching current1 A
Maximum current

NO: 1.2A

NC: 2A

Maximum commutable power

NO: 10 Va

NC: 20 Va

Cable glandPg 7 (per cavi in guaina Ø 6 o 7 mm)
Conductors cross-sectionMax. 1.5 mm2
Do not mount this indicator in proximity to magnetic fields.
Electrical featuresMAX temperature sensor
Power supplyAC/DC
Electric contacts

NO normally open

NC normally closed

Voltage /

Maximum current

250 Vac - 2 A(resistive loads)
115 Vac- 3A
24 Vdc - 3 A
12 Vdc - 4 A
Minimum current500 mA
Cable glandPg 7 (per cavi in guaina Ø 6 o 7 mm)
Conductors cross-sectionMax. 1.5 mm2
 
4Other executions

Special executions on request

  • Level indicators with stainless steel screws, nuts and washers.
  • Level indicators for use with fluids containing alcohol.
  • UV resistant transparent technopolymer level indicators.
  • MAX temperature electrical sensor with trigger threshold at 70°C or 90°C.
5Instructions of use

Connector assembly instructions

  1. Remove the connector from the indicator by unscrewing the set screw placed on the connector, take the contact holders out and loosen the cable gland.
  2. Slip on the cable into the connector (standard connector) and connect the wires to the terminals 1 and 2 for the functioning of the MIN level sensor, to the terminals 3 and earth for the functioning of the MAX temperature sensor.
  3. Assemble by pressing the contact holder into the connector in the required position.
  4. Screw the connectors to the indicator and then tighten the cable glands.
 

Scroll onderstaande tabel om meer te zien

Code

Product omschrijving

Aantal

Prijs

Bestel

CAD

L#

e

l1

d'-0.2

f

Gewicht (g)

d

a

l

f ±0.2

C

B

C#[Nm]

m

H

l2

Filter
470035168 HCV.127-E-ST-AX-NC-M12
€ 131,20
201.5 97 30 12.5 127 223 M12 21.8 50 127 31 20 12 28 25.5 29
470035167 HCV.127-E-ST-AX-NO-M12
€ 131,20
201.5 97 30 12.5 127 223 M12 21.8 50 127 31 20 12 28 25.5 29